Electronic Signs
LC6000 preparative high performance liquid chromatography system
P6100,P6250,P61000,P63000
Description
?
?
Description:
?
LC6000 preparative high performance liquid chromatography system can produce purifications of going to kg scale.
?
?
Applications:
?
Natural extracts synthetic mixtureschiral compounds etc
It can provide the highest chromatographic performance by combing with our dynamic axial compression columns.
Configuration List
- - - -
Item | PN | Product description | QTY | Unit |
LC6000 preparative hplc system | 1 | set |
1 | L.F.P61000 | P6000 HPLC pump, 1000ml pump head SST | 1 | pcs |
2 | L.F.UV6000 | UV6000?? UV-VIS Spectral photometer with preparative flow cell | 1 | pcs |
3 | I.IDEX.3725I-038 | Rheodyne manual injection valve (2ml sample loop) | 1 | pcs |
4 | ? | Preparative column(upon request) | 1 | pcs |
5 | L.F.S.090 | Start-up Kit for Preparative(500ml---1000ml) | 1 | pcs |
6 | A.G.103 | CXTH 3000 Chromatography Workstation | 1 | pcs |
? | ? | Special tool kit for preparative pump | Upon request |
? | ? | Accessories required |
- - - -
?
Note:
# # The following pump is available for this system:
100ml/min,250ml/min,500ml/min,1000ml/min
# # Both injection valve and pump is available
# Both prepacked column and DAC column is available
?
?
Technical parameter:
?
# Pump
Infusion Working Mode: Dual piston reciprocating pump
Pump Head: 100 mL or 250 mL Stainless steel pump head
Max Working Pressure: 20 MPa
Flow Rate Range: ( 0 ~ 100 ) mL / min or ( 0 ~ 250 ) mL / min
Flow Accuracy: ± 1.5 %
Flow Repeatability: RSD ≤ 1.0 %
Working Mode: Isocratic or Gradient Mode
?
# Detector
Wavelength Range: (190 - 700 ) nm
Light Source: D2 lamp (standard configuration), Tungsten lamp (optional available)
Wavelength accuracy: ± 2nm,
Wavelength repeatability: 0.4 nm
Detection Range: ( 0~2 ) AU
Baseline Noise: 3 X 10-5 AU
Baseline Drift: 1 X 10-3 AU/h
?
?
Competitive Advantage:
?
The Characteristics of LC3000-PCD Post-Column
Derivatization Analytical System
# Modular design
Optional single or double reaction core, which can be heated reaction at room temperature the reaction of two reactions;
Optional one, two or more derivatizing agent pumps
# Panel display, easy setup
Reactor core front panel display of the set temperature of the reaction and the actual temperature; Derivative front panel display of each reagent pump flow rate, pressure and pressure limit;
?
?
Competitive Advantage:
?
Preparative HPLC pump is double piston design
Developed server engine
Exported check valve and sealing ring
Providing high quality products for the customer
?
Read More
Beijing chuangxintongheng Science &Technology Co., Ltd.
Preparative HPLC System,Industrial HPLC,Analytical HPLC System
Address: Rm401,Huizhong Building,Shangdi 7 Street,Haidian Dsitrict,Beijing,China,
Beijing, Beijing
China, 100000
Tel: 86-010-82890257
Fax: 86-010-82899729