240VDC Battery Voltage High Frequency Online UPS Single Phase 10KVA

VT6KS(10KS)

Description

240VDC?Battery?Voltage?High?Frequency?Online?UPS?Single?Phase?10KVA
?
?
Quick Detail:
?
# 240VDC?battery?voltage
# Crest?factor:3:1
# Input:(120±5)VAC~?(275±5)VAC
# Output:220Vac
# Rate Capacity:6K-240VDC?battery?voltage
# Power factor:0.8

?
?
Specifications:
?

- - - -
Model | VT6K | VT6KS | VT10K | VT10KS |
Rating | 6KVA/4800W | 10KVA/8000W |
Input | Input?system | Single?phase?&?earth?ground |
Voltage?range | (120±5)VAC~?(275±5)VAC |
Power?factor | ≥0.99 |
Voltage?range?of?bypass | (60±5)VAC~?(300±5)VAC?(default:?60VAC~300VAC?
Could?be?adjusted?by?software) |
Output | Output?system | Single?phase?&?earth?ground |
Rated?voltage | 220VAC??① |
Power?factor | 0.8 |
Voltage?precision | ±1% |
Output?frequency | Normal?mode | 1.The?output?frequency?synchronizes?with?the?input?frequency?
when?the?input?frequency?is?in?the?range?of??46?Hz~?54?Hz
2.The?output?frequency?is?50Hz?when?the?input
?frequency?is?not?in?the?range?of?46?Hz~?54?Hz
3.Can?be?set?as?60Hz |
Battery?mode |
Inverter?overload?capacity
?(Utility?power,?25℃) | 105%±5%125%±5%Load?>?150%±5%,?300ms?transfer?to?bypass |
Transfer?time | 0ms?(Normal?mode←→?Battery?mode) |
<4ms?(Normal?mode←→Bypass?mode) |
Crest?factor | 3:1 |
Battery | Batteries?voltage | 192VDC |
Battery?quantity | 16????② |
Battery?Type | Sealed?maintenance-free?lead?–acid?battery?
of?battery?voltage?12V/7AH |
Backup?Time?(25℃) | Full?load≥5min?(Standard) |
Charge?current | Standard??1A | Long??6.5A |
①?Note1:?Output?voltage?can?be?set:?200V/208V/220V/230V/240V.
②?Note2:?240VDC?battery?voltage?can?be?choose |
- - - -

?
?
Zero power switch delay: When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensures stable power supply of operating system.
Active Load Management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.
Sufficient Expansion Slots: The pre-allocated smart slots enable flexibility in choice of USB cards,AS400 cards, CMC monitoring cards, SNMP cards, RS485 cards and EMD environment monitoring cards.
The load power factor is 0.8: it adapts the features of most current electric equipment and elevates the load-bearing capacity of the machines.
Generator Supportable:The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generators and provide safe and reliable power supply.
?
?

?

cheap prodocuts, china suppliers,

Read More

Previous

3KVA - 30KVA 220V AC Industrial Uninterruptible Power Supply Single Phase Online UPS...

Previous

Single Phase High Frequency Online UPS 240V 36VDC...

Shenzhen Ada Power Electronics Co.,Limited

Low Voltage Variable Frequency Drive,Solar Variable Frequency Drive,3 Phase Variable Frequency Drive

Address: Xinzhong Road Baishi Zhou Nanshan District,
Shenzhen, Guangdong
China, 518000

Tel: 86-755-86099322
Fax: 86-755-86099322

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多