General Parts
Description
Stainless Steel TEMI? Controlled Environment Chamber 40L for Drug Stability Test
?
?
1. Description
?
Temperature Humidity Chamber?is also called environment testing machine, used to test various types of materials for their tolerances of heat, coldness, dryness and wetness. It is widely used in quality inspection of electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical, building materials, medical and aerospace industries.
?
?
2. ?Technical parameter:
?
- - - -
Model
CZ-A-80 (A~G) CZ-A-150 (A~G) CZ-A-225 (A~G) CZ-A-408 (A~G)
Internal Dimensions WxHxD (cm) | 40x50x40 | 50x60x50 | 50x75x60 | 60x85x80 |
External Dimensions WxHxD (cm) | 90x136x94 | 100x146x104 | 100x161x117 | 110x171x137 |
Temperature Range | -70°C~+100°C(150°C)
(A:+25°C B:0°C C:-20°C D:-40°C E:-50°C F:-60°C G:-70°C) ? |
Humidity Range | 20%~98%R.H.(10%-98%R.H/5%~98%R.H is a special optional condition) ? |
Analytic Accuracy/evenness degree of?
Temperature and Humidity | ±0.1°C;±0.1%R.H./2.0°C;±3.0%R.H. |
Control Accuracy | ±0.3°C;±2.5%R.H. ? |
Temperature Rising/Falling Time | Approximately 4.0°C/minute; approximately1.0°C/minute? (& quot;5~10°C decrease per minute& quot; is a special optional condition) ?? |
Inner and Outer Materials | The whole set is SUS 304# stainless steel treated with mist. Inner box is stainless steel ? |
Insulation Materia | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials? ? |
Cooling System | Air cooling /single segment compressor (-20°C), air? water cooling /double segment compressor? ? |
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection?switch, over-humidity and over-temperature protection switch, fuses, failure warning system??? ? |
Accessories | Recorder (optional), watching window, 50mm testing hole, PL internal bulbs, partition plate, dry and wet ball gauze ? |
control panel | ?South Korea& quot;TEMI& quot;or Japan??s & quot;OYO& quot; Brand ??Optional ? |
Compressor | France??s & quot;Tecumseh& quot; Brand ? |
Power | 220VAC±10% 50/60Hz?? 380VAC±10% 50/60Hz ? |
- - - -
?
?
3. Corresponding standard :
# GB11158 temperature Chambers technical conditions
# GB10589-89 Chambers cryogenic technology
# GB10592-89 Chambers technology high and low temperature conditions
# Chambers technology GB/T10586-89 hot and humid conditions
# GB/T2423.1-2001 hypothermia Chambers Test Method
# High Temperature Test Method Chambers GB/T2423.2-2001
# GB/T2423.3-93 hot and humid Chambers Test Method
# Alternating hot and humid GB/T2423.4-93 Test Method
# GB/T2423.22-2001 temperature changes Test Method
# IEC60068-2-1.1990 low temperature Chambers Test Method
# IEC60068-2-2.1974 high temperature Chambers Test Method
# GJB150.3 High Temperature Test
# GJB150.4 Low Temperature Test
# GJB150.9 Damp Heat Test
?
4. Product?Feathers:
?
1.?Modern-design?appearance:?safe,?reliable?and?easy?to?operate.
2.?Easy?to?observe?the?tested?product:?double-layer?glass?view?window,?anti-sweat?electric?heater?
device,?high?brightness?PL?fluorescent?lamp.
3.?Double?insulated?door?seal?strip:?effectively?prevent?internal?temperature?leakage.
4.?External?water?supply?system:?convenient?to?supply?water?into?humidification?barrel,?and?recycle
?automatically.
5.?Refrigeration?&?dehumidification?system-?& quot;& quot;Tecumseh& quot;& quot;(France):?energy?saving,?low?noise,?stable?performance,?with?green?refrigerant(R23,?R404A)
6.?Imported?LCD?screen:?display?testing?value?,set?value,?time,?etc.
7.?Multi-segment?program:?can?be?quick?and?sloped?controlling?temp.?and?humidity.
8.?Mobile?pulley?&?positioning?foot?at?the?bottom?of?machine:?convenient?to?move?and?fix?location.
?
?
Read More
Dongguan Zhongzhi Testing Instruments Co., Ltd
Environmental Test Chamber,Corrosion Test Chamber,Temperature Humidity Chamber
Address: Room 516, 5/F, Hongji Building, Hongfu Road,
Dongguan, Guangdong
China, 511700
Tel: 86-0769-89369332
Fax: 86-0769-88808158