Portable Submersible Non Clog Sewage Pump , Single Stage Stainless Steel Centrifugal Pump


Application

- - - -
1 | Pasturage drainage. |
2 | Cabin ponding . |
3 | Civil and architectural engineering construction. |
- - - -

?
Feature

- - - -
1 | Which drive and discharge solids through pump flow channel. |
2 | Foreigh matters allowance up to 70% of discharge size. |
3 | Induction motor are F class insulation |
4 | motor protection grand is IP68. |
- - - -

?
?
?
Structure


- - - -
NO. | Part Name | Material |
GB | JIS |
1 | Handle | Q235 | SS40 |
2 | Motor cover | HT200 | FC200 |
3 | O-ring | NBR | NBR |
4 | Bearing | - | - |
5 | Rotor | - | - |
6 | Shaft | 3Cr13 | SUS420J2 |
7 | Bearing | - | - |
8 | Bracket | HT200 | FC200 |
9 | Mechanical seal | SiC-SiC | SiC-SiC |
10 | Impeller | HT200 | FC200 |
11 | Pump casing | HT200 | FC200 |
12 | Oil cover | HT200 | FC200 |
13 | O-ring | NBR | NBR |
14 | Stator | - | - |
15 | Motor casing | HT200 | FC200 |
16 | Cable | - | - |
- - - -

?
Performance parameters:

- - - -

Type | Motor | Pump | Weight
kg |
kW | hp | Phase | Pole | Fre. | Dia | Head | Capacity |
Hz | mm | in | m | L/min | m3/h |
DP51.5-50 | 1.5 | 2 | 3 | 2 | 50 | 50 | 2‘’ | 14.3 | 200 | 12 | 28 |
DP51.5-80 | 1.5 | 2 | 3 | 2 | 50 | 80 | 3‘’ | 7.5 | 500 | 30 | 36 |
DP52.2-80 | 2.2 | 3 | 3 | 2 | 50 | 80 | 3‘’ | 11.5 | 550 | 33 | 52 |
DP53.7-80 | 3.7 | 5 | 3 | 2 | 50 | 80 | 3‘’ | 16.7 | 600 | 36 | 60 |
- - - -

?
Type description:
?
DP51.5-50
DP: Submersible sewage pump
5: Frequency 5: 50Hz
1.5: Rated power(kW)
50: Outlet diameter (mm)

?

Starting:
# # When turning the water pump with hands, the water pump shall rotate flexibly, free from friction. Inch the engine to determine whether the rotating direction is correct (it shall rotate counter clockwise seen from the pump impeller). The inching time shall not last over 5 seconds to prevent the mechanical from being damaged.
# Close the gate valve of the delivery pipe.
# Power on the water pump. Switch on the gate valve of the delivery pipe gradually and adjust the pressure to the one marked on the nameplate of the pump (too low outlet pressure may cause large flow of the pump, which may lead to over-power operation.) after the pump is in normal operation


?

?

Shut down:
# # Switch off the gate valve of the delivery pipeline gradually and power off the pump.
# If the ambient temperature is lower than 0℃, the medium in the pump shall be discharged to prevent frost crack.
# The pump shall be disassembled, cleaned, oiled and packed for storage if unused in a long time.


Operation:

During the starting and operation process, readings on the gauge shall be observed; timely treatment shall be made if it is found in abnormality.

?

Work shop:

?

cheap prodocuts, china suppliers,

Read More

Previous

Non Clog Submersible Vortex Pump Mechanical Seal For Waste Water Treatment...

Previous

Single Stage Vertical Non Clog Sewage Pump , Water Semi Open Impeller Centrifugal Pumps...

GSD Industrial Co., Ltd.

Sewage Treatment Equipment,Submersible Sewage Pump,Self Priming Sewage Pump

Address: No.796, Yun Qiao Road,
Shanghai, Shanghai
China, 200000

Tel: 86-21-50550317
Fax: 86-21-58549706

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多