Optoelectronic Displays

Share us

Protection Relay Testing / 50 Overcurrent Relay 3066i

K3066i

Description

Protection Relay Testing / 50 Overcurrent Relay? 3066i

?

Relay protection test devices
1.Easy test
2.operation menu, Simple operation
3.Nominal input voltage:220VAC
4.Power:1000VA

?

?Friendly PC software for easy operation!

K30 series relay tester is extremely design for overseas user, with Friendly PC software as your need, unique features and functions helps you all the way!

?1.?Unique?self protection?system?assure?the?powerful?protection?when?instrument?is?operating, ?automatic?stop?the?output?when the?network?is?abnormal?;

2.?Unique?power?switch?and?amplifier?technology, ?so?the?output?precision?and?power?efficiency?and?factor

?are?increased, ?which?conforms?to?international?tendency?of?energy?save?and?environmental?protection;

3.?With?alarm?function?of?housing?grounding?testing?and?external?voltage?input, ?to?guaranty?personal?security;

4.?Two?in?one?of?meter?and?source, ?with?function?of?both?internal?and?external?testing, ?self-calibration, ?oscillograph, ?and?the?duration?of?each?oscillograph?reaches?50S?(optional?function);

5.?Offer?independent?Aux.?DC?to?tested?devices, ?0?~?300V/0.6A?(Poleless?and?adjustable);

6.?Function?of?transducer?and?energy?meter?testing?(optional?function);

7.?Testing?interface?offer?unique?output?monitoring?function?and?Pre-curve-tracing?function, ?helps?more?on?the?spot?analysis;

?

Technical?Data?of?K3066i

- - - -
Voltage?generators |
Setting? Range | 7-phase?AC?(L-N) | 7?x?0?...?300?V? |
2-phase?AC?(L-L) | 2?x?0?...?600?V |
Power | 7-phase?AC?(L-N) | 7?x?110VA, ?at?0?...?300?V |
2-phase?AC?(L-L) | 2?x?220VA, ?at?0?...?600?V |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed? at?0?...?300?V <0.02%?reading?+?0.01%?range?typical? at?0-300V |
Resolution | 1mV |
Current?generators |
Setting? Range | 6-phase?AC?(L-N) | 6?x?0?...?30?A |
3-phase?AC?(2L-N) | 3?x?0?...?60?A?(Group?A?II?B) |
1-phase?AC?(3L-N) | 1?x?0?...?180?A? |
Power | 6-phase?AC?(L-N) | 6x?450VA?, at?0?...?30A? |
3-phase?AC?(2L-N) | 3x?520VA, ?at?0?...?60A?(Group?A?II?B)? |
1-phase?AC?(3L-N) | 1?x?1000?VA, ?at?0?...?180A?(Max.) |
Accuracy | <0.07%?reading?+?0.06%?range?guaranteed?at?0-30A? <0.02%?reading?+?0.02%?range?typical?at?0-30A |
Resolution | 1mA |
Generators, ?general |
Frequency | Range | 0?...?1000?Hz |
Accuracy?/?drift | Error? Resolution | 0.001Hz |
Phase | Range | -?360°?...?+360° |
Accuracy?/?drift | Error? Resolution | 0.1° |
Timer | Range | Infinite |
Accuracy?/?drift | Error<0.1ms |
DC?generators |
Voltage?ranges | 0?...?300V/180W |
Current?ranges | 0?...?20A/300W |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed?at?0-300V? <0.04%?reading?+?0.02%?range?typical?at?0-300V |
<0.14%?reading?+?0.06%?range?guaranteed?at?0-20A <0.05%?reading?+?0.02%?range?typical?at?0-20A |
Resolution | 1mA;?1?mV |
Aux?DC?Supply |
Range | 0...300V/150W |
Binary?inputs |
Number | 8?pairs |
Compatible?Voltage | 10V?...?250V??DC |
Binary?outputs |
Number | 4?Pairs |
Capacity | 250V/3A????AC/DC |
Synchronization |
Synchronization?mode | GPS |
Harmonic |
Harmonic?overlap?times | 2?...?20?times |
Power?supply |
Nominal?input?voltage | 220VAC±20% |
Power | 1000VA |
Nominal?frequency | 47Hz….65Hz |
Environmental?conditions |
Operation?temperature | -5°C?...?55?°C |
Storage?temperature | -20°C?...?75?°C |
Humidity?range | 5%?...?90?%, ?non-condensing |
Weight | 20?KG |
Dimensions | 460(D)×140?(W)×360?(H)?mm |
PC?connection | RJ45, |
- - - -

?

K30?Series?Protection?Relay?Test?Set:

- - - -
Model | Channels | AC?Outputs |
K3063i?/?K3063Li | 10?output?channels | 6*30A/3*40A/4*300V |
K3030i?/?K3030Li | 7?output?channels | 3*30A/4*300V |
K3066 | 13?output?channels | 6*20A/3*40A/7*130V |
K3063 | 10?output?channels | 6*20A/3*40A/4*130V |
K3040 | 7?output?channels | 3*40A/4*130V |
K3030 | 7?output?channels | 3*30A/4*130V |
- - - -

Major?functions:

- - - -
Items | IEEE(R)?No. |
Synchronization?relay | ? |
Fault?transplay | ? |
GPS?Synchronization? | ? |
Overcurrent?relays | 50/76 |
Inverse?time?overcurrent?relays | 51 |
Undercurrent?relays | 37 |
Ground?fault?relays | 50 |
Directional?overcurrent?relays | 67 |
Directional?ground?fault?relays | 67N |
Overvoltage?relays | 59 |
Undervoltage?relays | 27 |
Directional?voltage?relays | 91 |
Directional?power?relays | 32 |
Power?factor?relays | 55 |
Differential?protection?(differential?circuits) | 87 |
Distance?protection?equipment?(phase?by?phase) | 21 |
Negative?sequence?overcurrent?relays | 46N |
Motor?overload?protection | 51/86 |
Automatic?reclosing?devices? | 79 |
Tripping?relays | 94 |
Voltage?regulating?relays | ? |
Overimpedance?relays, ?Z> | ? |
Underimpedance?relays, ?Z | ? |
Time-delay?relays | ? |
- - - -

?

cheap prodocuts, china suppliers,

Read More

Previous

Automation Protection Relay Testing K68i , Single Phase...

Previous

Single - phase 200A Relay Test Set K511 To Test AC / DC Relay with LCD Display...

Electric Automation Company

Protection Relay Testing,Relay Test Set,Relay Test System

Address: 6F, Block 4CD, TianAn Cyber Park,
Shenzhen, Guangdong
China, 518000

Tel: 86-755-83418941
Fax: 86-755-88352611

H5响应式定制设计
26种语言,SEO营销型网站


H5/响应式/营销型企业网站; 26种语言扩展;
覆盖: 英文、法语、德语、西班牙语、葡萄牙语、俄语、阿拉伯语、波斯语、日语、韩语
了解更多