Boilers & Power Equipment
Description
Item Unit
Rated effluent pressure Mpa 1
Rated effluent water temperature oC 115
Rated return water? temperature oC 70
Combustion mode Chain grate
Applicable coal AII AIII
Open grate area m2 21.33
Heated surface of boiler Proper m2 440
Heated area of boiler tail m2 233
The coal consumption at full load operation Kg/h 2938
Thermal efficiency % 170
Dust emission concerntration mg/Nm3 <80
Indentified thermal efficiency % 82.5
Max part size for transportation (L×W×H) mm 10700*3550*3400
Max part weight for transporation cargo t 41
Installed exterior size(L×W×H) mm 14000*4730*7820
Read More
Qingdao JGQ Boiler Technology Co., Ltd.
Steam boilers, hot water boilers, heat-conducting boilers
Address: No. 257, Haikou Road, Laoshan District, Qingdao, Shandong, China,
Qingdao, Shandong
China, 266000
Tel: 86 532 83770555
Fax: 86 532 88976387