Power Master(SA) Series Online HF UPS 6-20kva, is DSP controlled updated Online HF UPS,Specially for 110V/120V, 127V etc. power grid net.
It has high adaptability and flexibility anddesigned to provide an optimized price/performance ratio. Its cut-edge digital control technology of DSP (Digital Signal Processor), can greatly improve the product performance and system reliability, and deliver a compact integration with higher power density.
Perfect Application:
Network, data centre, servers and workstations, office etc.
Main Features:
1)High Frequency and double conversion
2) Fully digitized control
3) Output power factor:0.7(0.8OPTIONAL)
4)Input output 110V/120V/127V
5) DC192V
6) Environment protection
7) Smart RS232(SNMP card optional)
8)Cold start
?
- - - -
Model | PMA6000S | PMA6000L | PMA 10000S | PMA 10000L | PMA 20000S | PMA 20000L |
Capacity | 6KVA | 6KVA | 10KVA | 10KVA | 20KVA | 20KVA |
Phase | Single |
Input power factor | Above 0.98 |
Input distortion | < 5% |
Input voltage range | 60-140V |
Input frequency range | 45-55HZ |
Charging voltage | 220VDC |
Recharging current | 1A | 5A | 1A | 5A | 1A | 5A |
BATTERY TYPE | Free Maintenance Lead-Acid battery |
BATTERY CAPACITY | 16pcs 12v*9ah | External battery | 16pcs 12v*9ah | External battery | 16pcs 12v*9ah | External battery |
Output PF | 0.7/0.8 | 0.7/0.8 | 0.7/0.8 |
Rated voltage | 110v/120v/127v |
Output Frequency | 50/60HZ(AUTO SENSE) |
Voltage stability | Within 1.5% |
Output current crest factor | 3:1 |
Wave distortion | Linear load <3%, Nonlinear load <5% |
Over load ability | 105%~125%10min;125%~150% 1min;>150%10ms |
Transfer time | AC-battery, zero transfer time
By pass-Inverter, ? zero transfer time |
AC abnormal | Alarm every 4 seconds |
Battery low voltage | Keep alarm every 1 second |
Overload | Keep alarm every 0.5 second |
Display | High Definition LED and LCD, clear & friendly display interface |
Efficiency | above87%(full load) |
Protection | Output short circuit, Overload, Output low voltage, Battery low voltage, Over-temperature, etc |
communication | RS232(Standard), RS485 and SNMP card(optional) |
Working Temp. | 0~40℃ |
Relative humidity | 0~90%( No coagulation) |
Cooling | Intelligent speed-control Fan |
Input & output | Terminals |
Surge protection | IEC60664—1 Graded protection |
EMI | EN 55022? Grade A |
ESD | IEC 1000-4-2:Grade 3 |
EFT | IEC 1000-4-4:Grade 3 |
RS | IEC 1000-4-3:Grade 3 |
SURGE | IEC 1000-4-5:Grade 3 |
Weight(N/G)KG | 40/42 | 72/75 | 42/45 | 74/77 | 80/85 | 115/120 |
(W*D*H)mm | 260*570*717 |
? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
- - - -
All specifications subject to change without notice